{"product_id":"kohler-20kw-standby-generator-single-phase-120-240-volt-20rca","title":"Kohler 20kW Standby Generator Single Phase 120\/240-Volt | 20RCA","description":"\u003ch2\u003eKohler 20RCA\u003c\/h2\u003e \u003cp\u003eThe Kohler 20RCA standby generator with OnCue Plus brings extraordinary power for homes and businesses in an air-cooled configuration. The automatic RCA20 restores power 10 seconds after the outage shuts off power including a 5-Ton air conditioner, major appliances, and other circuits. The 20kW single-phase 120\/240-Volt generator supplies clean, low-distortion power for electronics and heavy motors.\u003c\/p\u003e \u003cp\u003eMeets US EPA Requirements. UL-2200 Listed.\u003c\/p\u003e \u003cp\u003eThe Kohler 20RCA 20kW Standby Generator powers all the appliances for a home or business including air conditioning, heating, lights, security, and office equipment. Seconds after a power outage turns out the lights, the 20RCA restores power. Runs on Natural Gas or Propane. Includes OnCue Plus Wireless Remote Management. Includes OnCue Plus Wireless Remote Management. Premium 5-Year 2000-Hour Warranty.\u003c\/p\u003e \u003cp\u003e*Automatic Transfer Switch Sold Separately.\u003c\/p\u003e \u003cp\u003e*Requires Group 51, 12-Volt, 500 CCA Battery\u003c\/p\u003e \u003ch2\u003e20kW Kohler 20RCA Generator\u003c\/h2\u003e \u003cp\u003eKohler RCA Generators are built in the USA with Heavy Duty Command Pro Commercial V-Twin Engines for exceptional starting power and reliability in any weather including hurricanes. When the power goes out, the 20RCA restores power in 10 seconds to keep appliances working and the lights on. Award winning Kohler Generators provide high quality power and powerful performance for homes and businesses.\u003c\/p\u003e \u003cp\u003eMade in the USA—Kohler manufactures the 20RCA Generator in the USA.\u003c\/p\u003e \u003cp\u003ePowerBoost Technology starts large loads including central air conditioners while it maintains power to other appliances. The 20RCA boasts an extraordinary 41kVA of motor starting capability. Premium quality power with exceptional voltage and frequency regulation and very low harmonic distortion.\u003c\/p\u003e \u003cp\u003eKohler designed and tested the Command Pro engine for heavy-duty applications in commercial environments. Hydraulic lifters eliminate break-in periods and valve adjustments. The engine operates at a constant speed regulated to 3600 RPM for 60 hertz AC current.\u003c\/p\u003e \u003ch2\u003e20RCA Generator Features and Benefits\u003c\/h2\u003e \u003cp\u003eBuilt with the Kohler RDC2 Controller. Manages the generator set and an RXT Automatic Transfer Switch (sold separately.) The 20RCA fits into any neighborhood landscape or commercial setting with a stylish enclosure rated to -30°F  and sound levels that compare to a central air conditioner. Meets National Fire Protection Association guidelines for 18-inch clearance to combustible materials. Check the local authority having jurisdiction for installation guidelines.\u003c\/p\u003e \u003cp\u003eFast, easy installation with a simple terminal block for field connections. Concrete mounting pads available to lower installation cost and time. Runs on Natural Gas or Propane—easily set the fuel type during installation.\u003c\/p\u003e \u003cp\u003eThe OnCue Plus Remote Management System allows homeowners and businesses to remotely manage their generator system from anywhere in the world with the OnCue Plus Mobile App for smartphones and tablets. OnCue connects the generator through the home or business wireless internet connection.\u003c\/p\u003e \u003ch2\u003eProduct Specifications\u003c\/h2\u003e \u003cdiv class=\"content\"\u003e \u003ch3 class=\"title\"\u003eModel\u003c\/h3\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eModel Number; 20RCA\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eManufacturer; Kohler Generators\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eMade In USA; Yes\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eRated Watts; 20kW\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eSurge Watts; 41 kVA\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eRated Amps; 83\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eVoltage; 120\/240 Volts Single Phase\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eA\/C Ton Rating; 5-Ton\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eEnclosure; Aluminum\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eUL Listed; UL-2200\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eDecibel Rating; 64 dBA Exercise \/ 69 dBA Full Load\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eType; Standby Generator\u003c\/p\u003e \u003c\/div\u003e \u003ch3 class=\"title\"\u003eFeatures\u003c\/h3\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eStarting System; Automatic\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eLow Oil Alert; Yes\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eMainline Breaker; 100-Amp\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eBattery Requirement; 12-Volt Group 51 500 CCA\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eMounting Pad; Yes\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eWeight; 555 lbs\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eDimensions; 47L x 26.2W x 32.2H\u003c\/p\u003e \u003c\/div\u003e \u003ch3 class=\"title\"\u003eWarranty Information\u003c\/h3\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eConsumer Warranty; 5-Year 2000-Hour Limited Warranty\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eCommercial Warranty; 5-Year 2000-Hour Limited Warranty\u003c\/p\u003e \u003c\/div\u003e \u003ch3 class=\"title\"\u003eEngine\u003c\/h3\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eEngine Brand; Kohler Commercial Command Pro\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eEngine Size; 999 cc\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eEngine RPM; 3600\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eCast Iron Sleeve; No\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eCooling System; Air Cooled\u003c\/p\u003e \u003c\/div\u003e \u003ch3 class=\"title\"\u003eAlternator\u003c\/h3\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eAlternator Type; 2-Pole Rotating Field\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eFrequency; 60 Hz\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eAuto Voltage Regulation; Yes\u003c\/p\u003e \u003c\/div\u003e \u003ch3 class=\"title\"\u003eFuel\u003c\/h3\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eFuel Type; Natural Gas or Propane\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eFuel Gauge; No\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eNG Power Capacity; 18kW\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eLP Power Capacity; 20kW\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eNG Consumption @ Full Load;  281 cubic-feet \/ hour\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eNG Consumption @ Half Load; 161 cubic-feet \/ hour\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eLP Consumption @ Full Load; 3.74 gal \/ hour\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"spec\"\u003e \u003cp class=\"label\"\u003eLP Consumption @ Half Load; 2.25 gal \/ hour\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"TITANPARTHUB","offers":[{"title":"Default Title","offer_id":52160888963303,"sku":null,"price":4251.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/7806\/3335\/files\/aa601627-kohler-20rca-front-left-view__26996__01940.jpg?v=1780566211","url":"https:\/\/titanparthub.com\/products\/kohler-20kw-standby-generator-single-phase-120-240-volt-20rca","provider":"TITANPARTHUB","version":"1.0","type":"link"}