{"product_id":"bell-gossett-series-hv-nfi-circulator-pump-model-102210-low-flow-applications","title":"Bell \u0026 Gossett Series HV NFI Circulator Pump | Model 102210 | Low-Flow Applications","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eThe Bell \u0026amp; Gossett 102210 is a compact, high-efficiency circulator from the Series HV NFI line, specifically engineered for low-flow, high-head applications in commercial and residential hydronic systems. This “Non-Flanged Inline” pump is perfect for tasks requiring precise fluid control, such as zone circulation, injection pumping, and heat exchanger loops where standard circulators are oversized.\u003c\/p\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eConstructed with a durable bronze body and featuring a high-temperature mechanical seal, this circulator offers excellent corrosion resistance for long-term reliability. Its compact, inline design allows for easy installation in tight spaces, while the threaded connections simplify integration into existing piping systems. With a fractional 1\/25 HP motor, this pump delivers just the right amount of power for specialized applications, ensuring energy-efficient operation without over-pumping the system.\u003c\/p\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eFor applications demanding precision, reliability, and compact design, the Bell \u0026amp; Gossett Series HV NFI circulator provides professional-grade performance in a space-saving package.\u003c\/p\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003e Technical Resources \u0026amp; Guides\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003ca href=\"https:\/\/blog\/zone-control-hydronic-systems\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eZone Control Systems for Hydronic Heating: Setup Guide\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003ca href=\"https:\/\/blog\/injection-pumping-guide\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInjection Pumping in Hydronic Systems: Principles \u0026amp; Applications\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003ca href=\"https:\/\/blog\/circulator-pump-troubleshooting\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTroubleshooting Small Circulator Pump Problems\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"ds-scroll-area _1210dd7\"\u003e \u003cdiv class=\"ds-scroll-area__gutters\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003c\/div\u003e \u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpecification Category\u003c\/th\u003e \u003cth\u003eDetail\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e102210\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBell \u0026amp; Gossett Series HV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFI (Non-Flanged Inline)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMotor HP\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e1\/25 HP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMotor Speed\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSingle-Speed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e120V, 1-Phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection Size\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e3\/4″ Female NPT\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eThreaded\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaximum Working Pressure\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e125 PSI \/ 8.6 Bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaximum Temperature\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e240°F \/ 116°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConstruction – Body\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBronze\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConstruction – Impeller\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eComposite\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eShaft Seal\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMechanical Seal\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eInline, pipe-mounted\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003e\u003cstrong\u003eWhat’s Included\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"ds-scroll-area _1210dd7\"\u003e \u003cdiv class=\"ds-scroll-area__gutters\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003c\/div\u003e \u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eIncluded\u003c\/th\u003e \u003cth\u003eNot Included \/ Required Separately\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e✓ Complete Circulator Assembly\u003c\/td\u003e \u003ctd\u003e✗ Pipe Sealant\/Teflon Tape\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e✓ 3\/4″ NPT Threaded Connections\u003c\/td\u003e \u003ctd\u003e✗ Isolation Valves\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e✓ Mechanical Seal\u003c\/td\u003e \u003ctd\u003e✗ Power Cord\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e✗ Mounting Support (if needed)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003e🛠️ Recommended for a Complete Installation\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003ca href=\"https:\/\/product\/bg-union-isolation-valves\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBell \u0026amp; Gossett 3\/4″ Union Isolation Valves\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eControl:\u003c\/strong\u003e \u003ca href=\"https:\/\/product\/taco-zone-control-panel\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTaco Zone Control Panel\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eAccessories:\u003c\/strong\u003e \u003ca href=\"https:\/\/product\/circulator-mounting-bracket\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCirculator Mounting Bracket\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003eComparison Table: Series HV NFI vs. Alternative Pumps\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"ds-scroll-area _1210dd7\"\u003e \u003cdiv class=\"ds-scroll-area__gutters\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-bar\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eFeature\u003c\/th\u003e \u003cth\u003eBell \u0026amp; Gossett Series HV NFI\u003c\/th\u003e \u003cth\u003eStandard Circulator\u003c\/th\u003e \u003cth\u003eECM Smart Circulator\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eLow-Flow, High-Head Specialized\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eGeneral Hydronic Circulation\u003c\/td\u003e \u003ctd\u003eHigh-Efficiency Systems\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eCompact, Space-Saving\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eStandard Size\u003c\/td\u003e \u003ctd\u003eStandard Size\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eGood for Application\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003ctd\u003eExcellent\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSingle-Speed\u003c\/td\u003e \u003ctd\u003eSingle\/Multi-Speed\u003c\/td\u003e \u003ctd\u003eVariable Speed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCost\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eSpecialized Application Pricing\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBudget-Friendly\u003c\/td\u003e \u003ctd\u003ePremium\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eIdeal For\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eZone Control, Injection Pumping\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMain System Circulation\u003c\/td\u003e \u003ctd\u003eEnergy-Conscious Applications\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQs)\u003c\/strong\u003e\u003c\/h3\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ1: What does “NFI” stand for in the model designation?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e NFI stands for “Non-Flanged Inline,” indicating this pump features threaded (NPT) connections instead of flanged connections, making it ideal for smaller pipe sizes and simpler installations.\u003c\/p\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ2: What are typical applications for this small circulator?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e The Series HV NFI is perfect for:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eZone control in hydronic heating systems\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eInjection pumping for temperature control\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eHeat exchanger loops\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eSolar thermal systems\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eSmall booster applications\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ3: Is this pump suitable for potable water systems?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e While bronze construction is often used in potable water applications, you should verify NSF\/ANSI 61 certification for this specific model before using in drinking water systems.\u003c\/p\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ4: What maintenance does this circulator require?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Maintenance includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003ePeriodic inspection for leaks at the mechanical seal\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eEnsuring proper system water quality\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eChecking electrical connections\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eVerifying proper operation through system monitoring\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ5: How do I determine if this pump is properly sized for my application?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Proper sizing requires calculating your system’s specific requirements:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eFlow rate (GPM)\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eHead loss (feet)\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eTemperature parameters\u003cbr\u003e Consult with a hydronic systems professional for accurate sizing.\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cblockquote\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eInternal Link:\u003c\/strong\u003e \u003cem\u003eLearn more about specialized pumping applications in our guide \u003ca href=\"https:\/\/blog\/injection-pumping-guide\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInjection Pumping Techniques\u003c\/a\u003e.\u003c\/em\u003e\u003c\/p\u003e \u003c\/blockquote\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003ePros and Cons\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"ds-scroll-area _1210dd7\"\u003e \u003cdiv class=\"ds-scroll-area__gutters\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-bar\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003ePros\u003c\/th\u003e \u003cth\u003eCons\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Ideal for space-constrained installations\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eLimited Application Scope:\u003c\/strong\u003e Designed for specific low-flow uses\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eBronze Construction:\u003c\/strong\u003e Excellent corrosion resistance\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eLow HP:\u003c\/strong\u003e Not suitable for main system circulation\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eEnergy Efficient:\u003c\/strong\u003e Right-sized power for specialized applications\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eSingle-Speed:\u003c\/strong\u003e Lacks modern variable speed capabilities\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Threaded connections simplify integration\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eSpecialized Use:\u003c\/strong\u003e May be overkill for general circulation needs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eProfessional Grade:\u003c\/strong\u003e Bell \u0026amp; Gossett quality and reliability\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eCost:\u003c\/strong\u003e Higher than basic fractional HP circulators\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003e\u003cstrong\u003eConclusion \u0026amp; Ideal Use Case\u003c\/strong\u003e\u003c\/h3\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eThe Bell \u0026amp; Gossett 102210 Series HV NFI circulator excels in specialized applications where precision, compact size, and reliability are paramount. It’s the ideal solution for sophisticated hydronic systems requiring accurate fluid control.\u003c\/p\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eThis pump is perfectly suited for:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eZone control in multi-zone heating systems\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eInjection pumping for temperature modulation\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eHeat exchanger primary\/secondary loops\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eSolar thermal system circulation\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eSmall commercial HVAC applications\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eIf you need a precision circulator for specialized low-flow applications and value compact design and professional-grade quality, the Bell \u0026amp; Gossett Series HV NFI is an excellent choice.\u003c\/p\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003e🔗 Official Technical Resource\u003c\/strong\u003e\u003c\/h3\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cem\u003eFor complete technical specifications, performance curves, and installation instructions, visit the\u003c\/em\u003e \u003cstrong\u003e\u003ca href=\"https:\/\/www.bellgossett.com\/literature-installation-operation-manuals\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBell \u0026amp; Gossett Product Documentation Portal\u003c\/a\u003e\u003c\/strong\u003e \u003cem\u003efor the most accurate and up-to-date information.\u003c\/em\u003e\u003c\/p\u003e","brand":"TITANPARTHUB","offers":[{"title":"Default Title","offer_id":52160962494695,"sku":null,"price":883.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/7806\/3335\/files\/0c89e717-Bell-Gossett-Circulator-Pump-1.png?v=1780566419","url":"https:\/\/titanparthub.com\/products\/bell-gossett-series-hv-nfi-circulator-pump-model-102210-low-flow-applications","provider":"TITANPARTHUB","version":"1.0","type":"link"}