{"product_id":"armstrong-e24-2-cast-iron-circulator-pump-model-182212-653-commercial-grade","title":"Armstrong E24.2 Cast Iron Circulator Pump | Model 182212-653 | Commercial Grade","description":"\u003ch2\u003e\u003cstrong\u003eArmstrong 182212-653 E24.2 Cast Iron Circulator Pump\u003c\/strong\u003e\u003c\/h2\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eThe Armstrong 182212-653 E24.2 is a heavy-duty, end-suction centrifugal pump built for demanding commercial and industrial circulation applications. Featuring robust cast iron construction and designed for continuous operation, this circulator pump delivers reliable performance in HVAC systems, industrial processes, and municipal water applications where durability and long service life are essential.\u003c\/p\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eEngineered with a flexible-coupled, base-mounted design, the E24.2 separates the pump and motor for enhanced serviceability and maintenance access. This configuration allows for straightforward motor replacement or service without disturbing the pump casing or piping connections. The pump’s heavy-duty construction includes precision-machined components and industrial-grade bearings, ensuring smooth operation and extended service intervals even in the most challenging environments.\u003c\/p\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eFor mechanical engineers, facility managers, and contractors who demand industrial-grade reliability for large-building systems or process applications, the Armstrong E24.2 provides the performance and durability needed for critical circulation duties.\u003c\/p\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003e Commercial Pumping Resources\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003ca href=\"https:\/\/blog\/base-mounted-pump-installation\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBase-Mounted Pump Installation Guide\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003ca href=\"https:\/\/blog\/commercial-hydronic-design\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCommercial Hydronic System Design\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003ca href=\"https:\/\/blog\/pump-maintenance-best-practices\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePump Maintenance Best Practices\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"ds-scroll-area _1210dd7\"\u003e \u003cdiv class=\"ds-scroll-area__gutters\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003c\/div\u003e \u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpecification Category\u003c\/th\u003e \u003cth\u003eDetail\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e182212-653\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eArmstrong E24 Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eE24.2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eCast Iron\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBase-Mounted, Horizontal\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCoupling\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFlexible Coupling\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eShaft Seal\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMechanical Seal\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaximum Pressure\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e175 PSI \/ 12.1 Bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaximum Temperature\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e250°F \/ 121°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFlanged\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMotor Mount\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eStandard NEMA Frame\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003e\u003cstrong\u003eWhat’s Included (Pump Only)\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"ds-scroll-area _1210dd7\"\u003e \u003cdiv class=\"ds-scroll-area__gutters\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003c\/div\u003e \u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eIncluded\u003c\/th\u003e \u003cth\u003eNot Included \/ Required Separately\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e✓ Pump Casing \u0026amp; Volute\u003c\/td\u003e \u003ctd\u003e✗ Motor (Required separate purchase)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e✓ Heavy-Duty Baseplate\u003c\/td\u003e \u003ctd\u003e✗ Coupling Guard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e✓ Shaft \u0026amp; Bearing Assembly\u003c\/td\u003e \u003ctd\u003e✗ Isolation Valves\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e✓ Mechanical Seal\u003c\/td\u003e \u003ctd\u003e✗ Suction Diffuser\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e✓ Impeller\u003c\/td\u003e \u003ctd\u003e✗ Installation Hardware\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e✓ Coupling Half\u003c\/td\u003e \u003ctd\u003e✗ Alignment Services\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003e🛠️ Recommended for Complete System\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eMotor:\u003c\/strong\u003e \u003ca href=\"https:\/\/product\/baldor-industrial-motor\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBaldor Industrial Motor\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003ca href=\"https:\/\/product\/flanged-isolation-valves\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eFlanged Isolation Valve Set\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e \u003ca href=\"https:\/\/product\/industrial-coupling-guard\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eIndustrial Coupling Guard\u003c\/a\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003eComparison Table: E24 Series vs. Alternative Pumps\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"ds-scroll-area _1210dd7\"\u003e \u003cdiv class=\"ds-scroll-area__gutters\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-bar\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eFeature\u003c\/th\u003e \u003cth\u003eArmstrong E24.2\u003c\/th\u003e \u003cth\u003eClose-Coupled Circulator\u003c\/th\u003e \u003cth\u003eVertical In-Line Pump\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eServiceability\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eExcellent (Easy motor access)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePoor\u003c\/td\u003e \u003ctd\u003eModerate\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaintenance Cost\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eLow (Component-level repair)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eHigh (Unit replacement)\u003c\/td\u003e \u003ctd\u003eModerate\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eVibration Control\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eExcellent (Base-mounted)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFair\u003c\/td\u003e \u003ctd\u003eGood\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFootprint\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eLarge Horizontal\u003c\/td\u003e \u003ctd\u003eCompact\u003c\/td\u003e \u003ctd\u003eVertical\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMotor Flexibility\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eHigh (Any manufacturer)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eLimited\u003c\/td\u003e \u003ctd\u003eLimited\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eIdeal Applications\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eLarge Systems, Continuous Duty\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSpace-limited\u003c\/td\u003e \u003ctd\u003eLimited floor space\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQs)\u003c\/strong\u003e\u003c\/h3\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ1: What applications is the E24.2 pump designed for?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e This pump is ideal for:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eLarge commercial building HVAC systems\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eIndustrial process water circulation\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eMunicipal water distribution\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eBoiler feed and condenser water systems\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003ePrimary\/secondary pumping applications\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ2: What are the advantages of a base-mounted design?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Base-mounted pumps offer:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eEasy Maintenance:\u003c\/strong\u003e Motor can be serviced independently\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eBetter Heat Dissipation:\u003c\/strong\u003e Separation reduces heat transfer\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eFlexible Motor Selection:\u003c\/strong\u003e Various manufacturers can be used\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eVibration Damping:\u003c\/strong\u003e Baseplate isolates vibration\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eAlignment Access:\u003c\/strong\u003e Easier to achieve proper alignment\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ3: What motor size is required for this pump?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Motor selection depends on your system’s flow and head requirements. The E24.2 frame accommodates various motor sizes, but you must consult the pump performance curve and system calculations to determine the exact horsepower needed.\u003c\/p\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ4: What maintenance does this pump require?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Regular maintenance includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003ePeriodic bearing lubrication\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eMechanical seal inspection\/replacement\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eCoupling alignment verification\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eVibration monitoring\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003ePerformance testing against original curves\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eQ5: How critical is proper installation alignment?\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eA:\u003c\/strong\u003e \u003cstrong\u003eExtremely critical.\u003c\/strong\u003e Misalignment is a leading cause of premature failure in base-mounted pumps. Laser alignment or reverse indicator methods are recommended during installation and routine maintenance.\u003c\/p\u003e \u003cblockquote\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eInternal Link:\u003c\/strong\u003e \u003cem\u003eLearn proper techniques in our \u003ca href=\"https:\/\/blog\/pump-alignment-guide\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePump Alignment Guide\u003c\/a\u003e.\u003c\/em\u003e\u003c\/p\u003e \u003c\/blockquote\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003ePros and Cons\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"ds-scroll-area _1210dd7\"\u003e \u003cdiv class=\"ds-scroll-area__gutters\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e \u003cdiv class=\"ds-scroll-area__horizontal-bar\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003ePros\u003c\/th\u003e \u003cth\u003eCons\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eExcellent Serviceability:\u003c\/strong\u003e Easy access to all components\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eMotor Not Included:\u003c\/strong\u003e Requires separate purchase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eHeavy-Duty Construction:\u003c\/strong\u003e Cast iron built for industrial service\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eLarge Footprint:\u003c\/strong\u003e Requires significant floor space\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eSuperior Vibration Control:\u003c\/strong\u003e Base-mounted design reduces noise\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eComplex Installation:\u003c\/strong\u003e Requires precise alignment\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eHigh Flexibility:\u003c\/strong\u003e Compatible with various motor brands\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eHigher Skill Required:\u003c\/strong\u003e Needs alignment expertise\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cstrong\u003eIdeal for Continuous Duty:\u003c\/strong\u003e Designed for 24\/7 operation\u003c\/td\u003e \u003ctd\u003e\n\u003cstrong\u003eHigher Initial Cost:\u003c\/strong\u003e More than close-coupled units\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003e\u003cstrong\u003eConclusion \u0026amp; Ideal Use Case\u003c\/strong\u003e\u003c\/h3\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eThe Armstrong 182212-653 E24.2 cast iron circulator pump is engineered for commercial and industrial applications where reliability, serviceability, and continuous operation are essential requirements.\u003c\/p\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eThis pump is perfectly suited for:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eLarge Commercial HVAC Systems\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eIndustrial Process Cooling Circuits\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eMunicipal Water Applications\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eCentral Utility Plants\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eHigh-Rise Building Mechanical Systems\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp class=\"ds-markdown-paragraph\"\u003eIf your application demands industrial-grade construction with the serviceability needed to minimize downtime in critical operations, the Armstrong E24.2 delivers the performance and reliability expected from a world-class pump manufacturer.\u003c\/p\u003e \u003chr\u003e \u003ch3\u003e\u003cstrong\u003e🔗 Official Technical Resource\u003c\/strong\u003e\u003c\/h3\u003e \u003cp class=\"ds-markdown-paragraph\"\u003e\u003cem\u003eFor performance curves, installation manuals, and engineering data, visit the\u003c\/em\u003e \u003cstrong\u003e\u003ca href=\"https:\/\/www.armstrongfluidhandling.com\/technical-data\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eArmstrong Fluid Handling Technical Hub\u003c\/a\u003e\u003c\/strong\u003e \u003cem\u003efor the most accurate and up-to-date information.\u003c\/em\u003e\u003c\/p\u003e","brand":"TITANPARTHUB","offers":[{"title":"Default Title","offer_id":52160963772647,"sku":null,"price":1444.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/7806\/3335\/files\/04e3b2af-Cast-Iron-Circulator-Pump-1.png?v=1780566419","url":"https:\/\/titanparthub.com\/products\/armstrong-e24-2-cast-iron-circulator-pump-model-182212-653-commercial-grade","provider":"TITANPARTHUB","version":"1.0","type":"link"}