{"product_id":"armstrong-410135-302-pump-709t-2-hp-bronze-circulating-pump","title":"Armstrong 410135-302 Pump 709T – 2 HP Bronze Circulating Pump","description":"\u003ch1 data-start=\"238\" data-end=\"288\"\u003e\u003cstrong data-start=\"240\" data-end=\"286\"\u003eArmstrong 410135-302 Circulating Pump 709T\u003c\/strong\u003e\u003c\/h1\u003e \u003cp data-start=\"290\" data-end=\"655\"\u003eThe \u003cstrong data-start=\"294\" data-end=\"340\"\u003eArmstrong 410135-302 Circulating Pump 709T\u003c\/strong\u003e is a high-performance, close-coupled horizontal pump built for \u003cstrong data-start=\"404\" data-end=\"450\"\u003elong service life and dependable operation\u003c\/strong\u003e in demanding HVAC and building service applications. Designed for ease of installation and maintenance, this pump is ideal for \u003cstrong data-start=\"578\" data-end=\"652\"\u003ecooling towers, heating systems, and general-purpose water circulation\u003c\/strong\u003e.\u003c\/p\u003e \u003chr data-start=\"657\" data-end=\"660\"\u003e \u003ch2 data-start=\"662\" data-end=\"681\"\u003e✅ Key Features\u003c\/h2\u003e \u003cul data-start=\"682\" data-end=\"1229\"\u003e \u003cli data-start=\"682\" data-end=\"798\"\u003e \u003cp data-start=\"684\" data-end=\"798\"\u003e\u003cstrong data-start=\"684\" data-end=\"702\"\u003eDurable Design\u003c\/strong\u003e – Built with bronze-fitted or all-bronze construction for corrosion resistance and longevity.\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"799\" data-end=\"915\"\u003e \u003cp data-start=\"801\" data-end=\"915\"\u003e\u003cstrong data-start=\"801\" data-end=\"825\"\u003ePEI (ULTEM) Impeller\u003c\/strong\u003e – High-strength, precision-engineered 4.375″ impeller ensures efficient water movement.\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"916\" data-end=\"1008\"\u003e \u003cp data-start=\"918\" data-end=\"1008\"\u003e\u003cstrong data-start=\"918\" data-end=\"937\"\u003eMechanical Seal\u003c\/strong\u003e – Inside single-spring mechanical seal for reliable leak protection.\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1009\" data-end=\"1127\"\u003e \u003cp data-start=\"1011\" data-end=\"1127\"\u003e\u003cstrong data-start=\"1011\" data-end=\"1040\"\u003eHigh-Efficiency Operation\u003c\/strong\u003e – 2 HP at 3500 RPM, with optional 1800 RPM configuration for flexible system design.\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1128\" data-end=\"1229\"\u003e \u003cp data-start=\"1130\" data-end=\"1229\"\u003e\u003cstrong data-start=\"1130\" data-end=\"1150\"\u003eEasy Maintenance\u003c\/strong\u003e – Close-coupled horizontal design reduces downtime and simplifies servicing.\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1231\" data-end=\"1234\"\u003e \u003ch2 data-start=\"1236\" data-end=\"1284\"\u003e Armstrong 410135-302 Pump Specifications\u003c\/h2\u003e \u003cdiv class=\"_tableContainer_1rjym_1\"\u003e \u003cdiv class=\"_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse\"\u003e \u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1286\" data-end=\"1933\"\u003e \u003cthead data-start=\"1286\" data-end=\"1328\"\u003e \u003ctr data-start=\"1286\" data-end=\"1328\"\u003e \u003cth data-start=\"1286\" data-end=\"1313\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1305\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e \u003cth data-start=\"1313\" data-end=\"1328\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1315\" data-end=\"1326\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody data-start=\"1373\" data-end=\"1933\"\u003e \u003ctr data-start=\"1373\" data-end=\"1409\"\u003e \u003ctd data-start=\"1373\" data-end=\"1401\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e \u003ctd data-start=\"1401\" data-end=\"1409\" data-col-size=\"md\"\u003e709T\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1410\" data-end=\"1452\"\u003e \u003ctd data-start=\"1410\" data-end=\"1438\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e \u003ctd data-col-size=\"md\" data-start=\"1438\" data-end=\"1452\"\u003e410135-302\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1453\" data-end=\"1526\"\u003e \u003ctd data-start=\"1453\" data-end=\"1481\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e \u003ctd data-start=\"1481\" data-end=\"1526\" data-col-size=\"md\"\u003eClose-Coupled Horizontal Circulating Pump\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1527\" data-end=\"1568\"\u003e \u003ctd data-start=\"1527\" data-end=\"1555\" data-col-size=\"sm\"\u003eConnection Size\u003c\/td\u003e \u003ctd data-start=\"1555\" data-end=\"1568\" data-col-size=\"md\"\u003e2″ x 1.5″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1569\" data-end=\"1619\"\u003e \u003ctd data-start=\"1569\" data-end=\"1597\" data-col-size=\"sm\"\u003eImpeller Size\u003c\/td\u003e \u003ctd data-start=\"1597\" data-end=\"1619\" data-col-size=\"md\"\u003e4.375″ PEI (ULTEM)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1620\" data-end=\"1656\"\u003e \u003ctd data-start=\"1620\" data-end=\"1648\" data-col-size=\"sm\"\u003eMotor Power\u003c\/td\u003e \u003ctd data-start=\"1648\" data-end=\"1656\" data-col-size=\"md\"\u003e2 HP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1657\" data-end=\"1736\"\u003e \u003ctd data-start=\"1657\" data-end=\"1685\" data-col-size=\"sm\"\u003eSpeed\u003c\/td\u003e \u003ctd data-start=\"1685\" data-end=\"1736\" data-col-size=\"md\"\u003e3500 RPM (3600 RPM standard, 1800 RPM optional)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1737\" data-end=\"1780\"\u003e \u003ctd data-start=\"1737\" data-end=\"1765\" data-col-size=\"sm\"\u003ePhase\u003c\/td\u003e \u003ctd data-start=\"1765\" data-end=\"1780\" data-col-size=\"md\"\u003eThree Phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1781\" data-end=\"1840\"\u003e \u003ctd data-start=\"1781\" data-end=\"1809\" data-col-size=\"sm\"\u003eConstruction Options\u003c\/td\u003e \u003ctd data-start=\"1809\" data-end=\"1840\" data-col-size=\"md\"\u003eBronze-fitted or All-Bronze\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1841\" data-end=\"1933\"\u003e \u003ctd data-start=\"1841\" data-end=\"1869\" data-col-size=\"sm\"\u003eApplications\u003c\/td\u003e \u003ctd data-start=\"1869\" data-end=\"1933\" data-col-size=\"md\"\u003eCooling towers, HVAC, building services, general circulation\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr data-start=\"1935\" data-end=\"1938\"\u003e \u003ch2 data-start=\"1940\" data-end=\"1960\"\u003e Applications\u003c\/h2\u003e \u003cul data-start=\"1961\" data-end=\"2128\"\u003e \u003cli data-start=\"1961\" data-end=\"1992\"\u003e \u003cp data-start=\"1963\" data-end=\"1992\"\u003e\u003cstrong data-start=\"1963\" data-end=\"1990\"\u003eCommercial HVAC systems\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1993\" data-end=\"2034\"\u003e \u003cp data-start=\"1995\" data-end=\"2034\"\u003e\u003cstrong data-start=\"1995\" data-end=\"2032\"\u003eCooling towers and chiller plants\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2035\" data-end=\"2076\"\u003e \u003cp data-start=\"2037\" data-end=\"2076\"\u003e\u003cstrong data-start=\"2037\" data-end=\"2074\"\u003eGeneral-purpose water circulation\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2077\" data-end=\"2128\"\u003e \u003cp data-start=\"2079\" data-end=\"2128\"\u003e\u003cstrong data-start=\"2079\" data-end=\"2126\"\u003eHeating and hot water recirculation systems\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"2130\" data-end=\"2133\"\u003e \u003ch2 data-start=\"2135\" data-end=\"2175\"\u003e❓ Frequently Asked Questions (FAQs)\u003c\/h2\u003e \u003cp data-start=\"2177\" data-end=\"2327\"\u003e\u003cstrong data-start=\"2177\" data-end=\"2235\"\u003e1. What type of seal does the Armstrong 709T pump use?\u003c\/strong\u003e\u003cbr data-start=\"2235\" data-end=\"2238\"\u003eIt comes equipped with an \u003cstrong data-start=\"2264\" data-end=\"2304\"\u003einside single-spring mechanical seal\u003c\/strong\u003e for leak resistance.\u003c\/p\u003e \u003cp data-start=\"2329\" data-end=\"2480\"\u003e\u003cstrong data-start=\"2329\" data-end=\"2378\"\u003e2. Can this pump operate at different speeds?\u003c\/strong\u003e\u003cbr data-start=\"2378\" data-end=\"2381\"\u003eYes. It is designed for \u003cstrong data-start=\"2405\" data-end=\"2428\"\u003e3600 RPM (standard)\u003c\/strong\u003e and can be configured for \u003cstrong data-start=\"2455\" data-end=\"2477\"\u003e1800 RPM operation\u003c\/strong\u003e.\u003c\/p\u003e \u003cp data-start=\"2482\" data-end=\"2652\"\u003e\u003cstrong data-start=\"2482\" data-end=\"2530\"\u003e3. What materials are used for construction?\u003c\/strong\u003e\u003cbr data-start=\"2530\" data-end=\"2533\"\u003eThe pump is available in \u003cstrong data-start=\"2558\" data-end=\"2575\"\u003ebronze-fitted\u003c\/strong\u003e or \u003cstrong data-start=\"2579\" data-end=\"2606\"\u003eall-bronze construction\u003c\/strong\u003e for durability and resistance to corrosion.\u003c\/p\u003e \u003cp data-start=\"2654\" data-end=\"2807\"\u003e\u003cstrong data-start=\"2654\" data-end=\"2714\"\u003e4. Where is the Armstrong 410135-302 pump commonly used?\u003c\/strong\u003e\u003cbr data-start=\"2714\" data-end=\"2717\"\u003eIt is widely used in \u003cstrong data-start=\"2738\" data-end=\"2804\"\u003eHVAC systems, cooling towers, and commercial building services\u003c\/strong\u003e.\u003c\/p\u003e \u003cp data-start=\"2809\" data-end=\"2937\"\u003e\u003cstrong data-start=\"2809\" data-end=\"2844\"\u003e5. Is the impeller replaceable?\u003c\/strong\u003e\u003cbr data-start=\"2844\" data-end=\"2847\"\u003eYes, the \u003cstrong data-start=\"2856\" data-end=\"2880\"\u003ePEI (ULTEM) impeller\u003c\/strong\u003e is serviceable and designed for long-term performance.\u003c\/p\u003e","brand":"TITANPARTHUB","offers":[{"title":"Default Title","offer_id":52160961773799,"sku":null,"price":1554.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/7806\/3335\/files\/47c99047-Pumps-Armstrong-410135-302-Circulating-Pump-709T.jpg?v=1780566419","url":"https:\/\/titanparthub.com\/products\/armstrong-410135-302-pump-709t-2-hp-bronze-circulating-pump","provider":"TITANPARTHUB","version":"1.0","type":"link"}